Status:
base class, extends NXobject, version 1.0
Description:
(required) Template of the top-level NeXus group which contains all the data and associated information that comprise a single measurement. It is mandatory that there is at least one group of this type in the NeXus file.
Symbols:
No symbol table
Structure:
@IDF_Version: NX_CHAR
ISIS Muon IDF_Versiontitle: NX_CHAR
Extended title for entryexperiment_identifier: NX_CHAR
Unique identifier for the experiment, defined by the facility, possibly linked to the proposalsexperiment_description: NX_CHAR
Brief summary of the experiment, including key objectives.collection_identifier: NX_CHAR
User or Data Acquisition defined group of NeXus files or NXentrycollection_description: NX_CHAR
Brief summary of the collection, including grouping criteria.entry_identifier: NX_CHAR
unique identifier for the measurement, defined by the facility.definition: NX_CHAR
(alternate use: see same field in NXsubentry for preferred)
Official NeXus NXDL schema to which this file conforms.
This field is provided so that NXentry can be the overlay position in a NeXus data file for an application definition and its set of groups, fields, and attributes.
It is advised to use NXsubentry, instead, as the overlay position.
@version: NX_CHAR
NXDL version number@URL: NX_CHAR
URL of NXDL filedefinition_local: NX_CHAR
start_time: NX_DATE_TIME
Starting time of measurementend_time: NX_DATE_TIME
Ending time of measurementduration: NX_INT {units=NX_TIME}
Duration of measurementcollection_time: NX_FLOAT {units=NX_TIME}
Time transpired actually collecting data i.e. taking out time when collection was suspended due to e.g. temperature out of rangerun_cycle: NX_CHAR
Such as “2007-3”. Some user facilities organize their beam time into run cycles.program_name: NX_CHAR
revision: NX_CHAR
Revision id of the file due to re-calibration, reprocessing, new analysis, new instrument definition format, ...
@comment: NX_CHAR
pre_sample_flightpath: NX_FLOAT {units=NX_LENGTH}
This is the flightpath before the sample position. This can be determined by a chopper, by the moderator or the source itself. In other words: it the distance to the component which gives the T0 signal to the detector electronics. If another component in the NXinstrument hierarchy provides this information, this should be a link.(data): NXdata
The required data groupexperiment_documentation: NXnote
Description of the full experiment (document in pdf, latex, ...)notes: NXnote
Notes describing entrythumbnail: NXnote
A small image that is representative of the entry. An example of this is a 640x480 jpeg image automatically produced by a low resolution plot of the NXdata.
@mime_type: NX_CHAR
The value should be an image/*
Obligatory value: image/*
(characterization): NXcharacterization
(user): NXuser
(sample): NXsample
(instrument): NXinstrument
(collection): NXcollection
(monitor): NXmonitor
(parameters): NXparameters
(process): NXprocess
(subentry): NXsubentry